Read e-book online ABB Electrical Installtion Handbook PDF

By Malestorm

ISBN-10:

ISBN-13: 1301301301001

ISBN-10: 6086511993

ISBN-13: 9786086511999

ISBN-10: 6100812002

ISBN-13: 9786100812002

Show description

Read Online or Download ABB Electrical Installtion Handbook PDF

Best technique books

Get Woodworking Shopnotes 036 - Miter Trimmer PDF

Each web page of ShopNotes journal will make you a greater woodworker, since you get extra woodworking plans, extra woodworking innovations, extra woodworking jigs, and extra approximately woodworking instruments — and never a unmarried advert. For greater than 25 years, woodworkers have grew to become to ShopNotes for the main special woodworking plans and woodworking guidance on hand at any place.

Download PDF by Thucydides Xanthopoulos (auth.), Thucydides Xanthopoulos: Clocking in modern VLSI systems

Clocking in sleek VLSI structures covers quite a lot of matters regarding microprocessor clocking together with distribution, flop layout, inductive strategies, section noise and jitter, hold up lock innovations, resiliency and different innovations to deal with method edition and actual layout features. The publication comprises rigorous analytical therapy for a couple of vital themes reminiscent of timing uncertainty due statistical spatial and temporal phenomena, metastability, jitter within the time and frequency area and supply-induced clock noise.

Design of wood aircraft structures by Forest Products Laboratory PDF

Ready by way of wooded area items Laboratory, woodland provider, U. S. Dept. of Agriculture and by way of ANC-23 Panel on Sandwich building for airplane, Subcommittee on Air Force-Navy-Civil plane layout standards, plane Committee, Munitions Board.

Additional resources for ABB Electrical Installtion Handbook

Sample text

For all the CT sizes t1=18s, except with 320 A CT (T4) and 630 A (T5) where t1=12s. 8 x In, I3 max = 9,5 x In (1) For PR223DS the L protection function can be set to I1 = 0,18… 1 x In ABB SACE - Protection and control devices 1SDC210001F0004 10-2 10-2 T4 10-3 10-1 1 10 T6 T5 T5 T6 400 630 630 800 1000 1 x In 10 I [kA] Note: The dotted curve of function L corresponds to the maximum delay (t1) which can be set at 6xl1, in the case where 320 A CTs are used for T4 and 630 A for T5. For all the CT sizes t1=18s, except with 320 A CT (T4) and 630 A (T5) where t1=12s.

2 Trip curves 3 General characteristics 3 General characteristics Trip curve electronic releases Trip curve electronic releases S7 PR212/MP 103 13 I Function Emax PR121/P PR331/P 104 L- I Functions 103 12 11 102 10 t [s] 9 t [s] 8 102 7 10 6 101 1 1 10-1 1SDC200100F0001 10-1 10-2 10-2 10-3 10-1 PR212/MP 1 1,05 101 102 GSIS0219 10-1 10-3 1 101 102 x In x In I3 (6 - 7- 8 - 9 - 10 - 11 - 12 - 13 - OFF) x In The tolerances are according to IEC 60947-4-1. 2 Trip curves 3 General characteristics 3 General characteristics PR123/P release – Function L in compliance with Std.

84 I2t OFF 10-1 10-1 ABB SACE - Protection and control devices 10-2 10-3 10-1 1 10 102 I [kA] Note: The dotted curve for functional corresponds to the maximum delay (t1) wich can be set at 6 x I1, in the case where 320A CTS are used for T4 and 630A for T5. For all the CT sizes the maximum delay t1 is equal to 18s, except for 320 A CT (T4) and 630 A (T5) where t1=12s. 8 x In, I3 max = 9,5 x In Only the electronic settings are available. 12 12 I2t ON 10 10 102 102 1 1 T4 T5 400 I2t OFF 10-1 10-1 T5 630 T7 S,H,L 10-2 10-2 T6 630 T7 V T6 800 T6 1000 10-3 10-3 10-1 1 10 1 x In 2 10 I [kA] 10-1 1 10 10 x In 102 I [kA] Note: For all the CT sizes the maximum delay t1 is equal to 18s, except for 320 A CT (T4) and 630 A (T5) where t1=12s.

Download PDF sample

ABB Electrical Installtion Handbook by Malestorm


by Kevin
4.1

Rated 4.35 of 5 – based on 49 votes